Controlling fan speed on a Barani Design prototype fan-aspirated radiation shield

Posted on April 28, 2023May 10, 2023 by meteodrenthe

Recently, I was fortunate to receive a new prototype model of the fan-aspirated MeteoShield Pro from Barani Design. On this version, the solar panels are replaced with two power wires, making it possible to connect an external power source, allowing the fan to be active 24 hours a day. Varying fan rpm is possible by…

The B parameter vs. Steinhart-Hart equation

Posted on September 7, 2022March 10, 2023 by meteodrenthe

In my previous post about reading thermistors with a Wemos D1 Mini, I observed resulting output seemed a bit high at lower temperatures, while readings were lower compared to other sensors at higher temperatures. (If you haven’t read that post yet, you may want to check that first in order to understand the starting point…

Trying out a Vaisala DTR504

Posted on July 29, 2022March 13, 2023 by meteodrenthe

I’ve pretty much settled on my current radiation shield setup. Based on personal research alongside that of others, I do not think I will find an affordable radiation shield that can outperform the Barani MeteoShield Pro. Whenever I have doubts about radiation errors, the results produced by sensors inside my actively ventilated Apogee TS-100 will…

Active versus passive ventilation under high radiation

Posted on June 28, 2022July 3, 2022 by meteodrenthe

It’s June. An ideal month in the Northern Hemisphere to observe the effectiveness of radiation shields under high solar radiation. Two of my main sensor setups are a passively ventilated Barani MeteoShield Pro with an SHT35 sensor and the actively ventilated Apogee TS-100 with PT100 sensor. In theory, there should be situations where the Barani…

Temperature sensor responsiveness (part 2)

Posted on May 15, 2022March 13, 2023 by meteodrenthe

In February I wrote a post about the responsiveness of the temperature sensors I am using. One caveat I noted then, was that I was comparing SHT35 sensors with PT100 sensors while the latter were actively ventilated and the first were not. In the mean time I made a few changes to my setup. Most…

Temperature sensor responsiveness

Posted on February 6, 2022February 7, 2022 by meteodrenthe

The passing of a sharp weather front, accompanied by a sudden increase or decrease in temperature, is a good occasion to analyze temperature sensor behavior. Especially apparent becomes the responsiveness of different sensors. February 4th 2022 didn’t see any spectacular weather, but during the afternoon a cold front passed over which caused a very abrupt…

Apogee TS-100 first impressions

Posted on August 19, 2021September 16, 2021 by meteodrenthe

I was losing the last light and had to get a flash light while connecting the last wires Tuesday evening (August 17th), but I have the TS-100 up and running. Without battery backup for now. I will fix that later. Adding this new shield to my setup has triggered a whole series of new tests…

Project Apogee part 3: controlling the TS-100

Posted on August 11, 2021September 21, 2023 by meteodrenthe

In my previous post I addressed the power supply needed to run the Apogee Instruments TS-100 fan aspirated shield in my setup. The next step is building a controller for the fan that allows me to vary the fan speed and read the actual rpm being achieved. The idea is that the controller can query…

Project Apogee part 2: power supply

Posted on August 8, 2021August 26, 2021 by meteodrenthe

Project Apogee requires me to rethink the power supply of my weather station. When I start writing this, the Meteodrenthe weather station runs on solar power only. The Davis components have their own panel inside the transmitters. Other custom elements use 2 watt 6 volt panels by Voltaic Systems. This has been an ideal solution…

Project Apogee part 1: fan aspiration

Posted on July 20, 2021December 27, 2021 by meteodrenthe

My big project for the summer of 2021 is adding a fan aspirated radiation shield to my setup. My primary shield – the Barani MeteoShield Pro – is a superb product, but a passive shield it remains. It suffers from overheating in windless conditions. Those conditions do not occur too often at my location, but…

My personal weather station is located in a small township in the North of the Netherlands.

This blog records updates to my setup, development of components, weather reports and anything related.

Real time data generated by the weather station can be found on meteodrenthe.nl.

Some products and technologies in use:

Davis Vantage Pro 2

Davis AirLink

Davis WeatherLink Live

Barani MeteoShield Pro

Apogee Instruments TS-100

Davis 7714 radiation shield

MetSpec RAD14 radiation shield

Vaisala DRT504

Siap+Micros SMarT CELLino

Wemos D1 Mini microcontrollers

Bosch BMP280/BMP3xx pressure sensors

Sensirion SHT35 temp/hygro sensor

PT100 temperature sensor

10K NTC thermistors

Adafruit breakout boards

ADS1115 analog-to-digital converter

Light intensity sensors

Voltaic Systems solar panels

Foscam FI9900P weather cam

Raspberry Pi Zero W

Custom printed circuit boards

C++ (Arduino code)

Java (server backend)

Angular Framework

Twitter feed is not available at the moment.
©2025 meteodrenthe.nl | Built using WordPress and Responsive Blogily theme by Superb